Diesel generator Cummins 292 kW

Diesel generator
Cummins 292 kW

Power, kW
292
Voltage (V)
400/230
Execution
Soundproof Enclosure
Manufacturer / Model
Cummins / QSN14-G1
ASK FOR PRICE
Подписаться
General characteristics
Power, kW
292
Voltage (V)
400/230
Execution
Soundproof Enclosure
Rated power, kVA
365
Maximum power, kW
352
Maximum power, kVA
440
Number of phases
3
Power Command
Cummins
Fuel tank capacity
450
Series
PREMIUM
Power factor
0.8
Frequency, Hz
50
Rated current (A)
576
The volume of the cooling system (l)
51
Fuel consumption at 75% power l/h
61.05
Fuel consumption at 100% power l/h
77.69
Emergency stop system
yes
Fuel level sensor
yes
Battery disconnect
yes
Muffler
yes
Overall dimensions (L; W; H; mm)
5500х1900x2150
Weight, kg
6165
Complete
Full
Engine Manufacturer
Cummins
Article for price list
CumminsOriginal292QSN14-G1HCI444F-2
Engine
Manufacturer / Model
Cummins / QSN14-G1
Rated power, kW
352
Maximum power, kW
-
Number of cylinders
6
Arrangement of cylinders
In-line
Engine cycle
4
Engine displacement (l)
14
Cooling system
Liquid
Crankshaft speed (rpm)
1500
Cylinder diameter (mm)
140
Stroke (mm)
152
Cylinder compression ratio
16.5:1
Speed ​​controller
Electronic
Onboard electrical equipment voltage, (V)
24
Starting device (starter)
24B
Specific fuel consumption (g/kW*h)
-
Fuel filter type
-
Recommended oil type
SAE 15W40
Oil filter type
-
Specific oil consumption (g/kW*h)
-
Oil system capacity (l)
38.6
Fan, (mm), type
-
Weight, kg
1706 (with radiator)
Fuel type
Diesel
Overall dimensions (L;W;H; mm)
1502x888x1219
Generator
Manufacturer / Generator Model
Stamford / HCI444F
Continuous power (kW)
320
Excitation system
-
Generator type
Synchronous
Voltage (V)
400/230
Number of phases
3
Efficiency, %
-
Winding pitch
2\3
Number of support bearings
1
Degree of insulation
H
Power factor (cos)
0.8
Voltage regulation accuracy (± %)
1.5
Voltage Regulator
yes
Warranty period (months)
12
Controller
Manufacturer / Model controller
Cummins / PCC 1,2
Power consumption, W
-
Alarm signal for unsuccessful start of the genset
yes
General alarm horn
yes
Alarm signal for general warning
yes
Battery voltage monitoring
yes
Frequency meter
yes
Hour counter
yes
Fuel level indicator in the tank
yes
Engine speed display
-
Phase sequence indicator
-
Coolant temperature display
yes
Oil pressure indication
yes
Battery voltage indication (V)
yes
Indication of active power on 3f. (kW)
yes
Power indication (kW)
-
Power indication (kVA)
yes
  Цена по запросу
FIND OUT THE COST
  Цена по запросу
FIND OUT THE COST
  Цена по запросу
FIND OUT THE COST